Pipe Heating Cable for Electric Freeze Protection #PHC
PHC heating cable, pre-assembled and ready-to-install, prevents pipes from freezing, keeping water flowing to -40°. PHC cables operate on 230 Volts AC and are suitable for use on water-filled plastic and metal pipes.
- Pre-assembled, Ready to install
- Weather resistant PVC
- Wattage: 12W/m 17W/m
- Voltage: 110-120V,208-240V
- Diameter: 7mm×4.2mm
- Approvals: CE UKCA EAC
- Main application: Water Pipe Freeze Protection
- General
- Specification
PHC Electric Water Pipe Freeze Protection Cable
Icoheat, the player in residential pipe freeze protection, presents the PHC Series pipe heating system.
Preassembled and ready-to-install, PHC heating cable prevents pipes from freezing, keeping water flowing to -40°. Using an energy saving thermostat, PHC cables operate on 230 Volts AC and are suitable for use on water-filled plastic and metal pipes. This system can be installed with the confidence that it will operate for years without requiring service. All components are made of the highest quality materials and are tested during critical points in the manufacturing process.
Benefits:
- Pre-assembled, no extra assemble work
- Robust and safe cable structure
- Easy & simple to install
- Almost no service after install
- Long life-time
- 2 years manufacturer warranty
Simple to install
The PHC Series system is easy to buy and to install, engineered in 2M increments (up to 49m) to accommodate many pipe lengths with diameters up to 4cms. Simply run the cable straight along the pipe and valves according to the included instructions, affix with our premium application tape and insulation, then plug into a ground fault protected electrical outlet.
This system requires no special wiring or assembly. Simply run cable straight along pipe and valves according to instructions in package, affix with premium application tape, insulate, and plug into a ground fault protected electrical outlet.
WARNING:
Do not spiral cable around pipe or cross cable over itself. Do not use one run of cable for two different pipe runs. Failure to comply may result in overheating and fire.
PHC heating cable
consists of tough XLPE inner insulation, a continuous ground braid, and weather resistant PVC (high-low temperature) out jacket. The cable is integrated an energy saving thermostat to control temperature.
| Item No. | Length(M) | Wattage (W/m) | Output @230V~(w) | Current @230V (A) | Resistance(Ω) |
| PHC-24-2 | 2 | 12 | 24 | 0.1 | 2204.2 |
| PHC-48-4 | 4 | 12 | 48 | 0.21 | 1102.1 |
| PHC-72-6 | 6 | 12 | 72 | 0.31 | 734.7 |
| PHC-96-8 | 8 | 12 | 96 | 0.42 | 551 |
| PHC-120-10 | 10 | 12 | 120 | 0.52 | 440.8 |
| PHC-180-15 | 15 | 12 | 180 | 0.78 | 293.9 |
| PHC-240-20 | 20 | 12 | 240 | 1.04 | 220.4 |
| PHC-300-25 | 25 | 12 | 300 | 1.3 | 176.3 |
| PHC-34-2 | 2 | 17 | 34 | 0.15 | 1555.9 |
| PHC-68-4 | 4 | 17 | 68 | 0.3 | 777.9 |
| PHC-102-6 | 6 | 17 | 102 | 0.44 | 518.6 |
| PHC-136-8 | 8 | 17 | 136 | 0.59 | 389 |
| PHC-170-10 | 10 | 17 | 170 | 0.74 | 311.2 |
| PHC-204-12 | 12 | 17 | 204 | 0.89 | 259.3 |
| PHC-238-14 | 14 | 17 | 238 | 1.03 | 222.3 |
| PHC-306-18 | 18 | 17 | 306 | 1.33 | 172.9 |
| PHC-629-37 | 37 | 17 | 629 | 2.73 | 84.1 |
| PHC-833-49 | 49 | 17 | 833 | 3.62 | 63.5 |
| Heating Cable Specification | Thermostat Specification | |||
| Nominal Voltage | 230V~50/60Hz | Functions | On/Off Control | |
| Conductor | Two conductors | Supply Voltage | AC 250V Max. | |
| Inner insulation | XPLE | Max switching current | AC240V/10A | |
| Screen | Braid | Setting Temp | 3°C | |
| Out sheath | Anti-UV PVC | Ambient range | -40°C~105°C | |
| Cable Shape | Flat | Life: | 100,000 electrical operations at rated load. | |
| Cable thickness | 7mm×4.2mm | |||
| Output power | 12W/M 15w/M | Cold lead | 2M | |
| Resist Tolerance | -5%~10% | Min installs temp | -10°C | |